IMJ00503 V3E.DOC Page 32 of 40 19.02.2009
6.2.10 Switching Point Output 1 or 2
Switching Point Output 1 or 2 corresponds to the trigger threshold of alarm output 1 or 2
respectively.
The trigger threshold behaviour is user-definable. For settings of this kind, a switching hysteresis
parameter is provided (refer to section 6.2.11).
6.2.11 Hysteresis Output 1 or 2
Hysteresis Output 1 or 2 corresponds to the switching hysteresis of alarm output 1 and 2
respectively.
Your settings for switching hysteresis define:
how a switching output will respond to the positive or negative
excession of a trigger threshold, depending on the mathematical sign
of a hysteresis value
what range will be covered by the switching output, depending on the
amount of hysteresis.
The following table shows switching output behaviour depending on the mathematical sign of
hysteresis:
Trigger threshold
positively exceeded
Trigger threshold
negatively exceeded
Positive hysteresis HIGH LOW
Negative hysteresis LOW HIGH
Table 3
Fig. 10: Behaviour of digital switching output for positive and negative hysteresis
6.2.12 Diagnostic Interval
Diagnostic Interva l allows you to define how often diagnostic reports are to be output. A
diagnostic report includes information about (but not limited to) the inner device temperature. For
generation of diagnostic data, a running distance measurement will be interrupted!
The available setting range for Diagnostic Interval is from 0 to 10000. The time scale is 100
msec. If Diagnostic Interval is set to “0”, diagnostic data will only be output if there was an error.
Consequently, a setting of “10000” for Diagnostic Interval will correspond to an interval of 1000
sec.