Sentek LMC-J-0040-1 Instrukcja Użytkownika Strona 35

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 39
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 34
IMJ00503 V3E.DOC Page 35 of 40 19.02.2009
7. Malfunction & Error Reports
8.1 Malfunction
Error situation Cause Action for removal
No data coming via
Profibus
Faulty Profibus configuration Check Profibus configuration
Device error (Ext.
diagnosis)
Hardware problems Reship LMC J 0050 3 for repair,
contact technical support
8.2 Errror Report Outputs via Profibus
Code Cause Action for removal
E15 Excessively poor reflexes Use target board, observe minimum
requirement on
measuring distance (> 0.1 m)
E16 Excessively strong reflexes
Use target board, do mot measure against reflecting
surfaces
E17 Too much steady light (e.g. sun) Mount LMC J 0050
3 in such a position that
excessive incidence of steady light
is prevented,
extend glare protection tube, provide additional
light shielding, e.g. protective cap
E18
Only in DX mode: too much
difference between measured
and pre calculated value
Check path from distance meter to target being
measured for obstacles
E23 Temperature below –10°C Provide ambient temperature > 10°C
E24 Temperature above +60°C Provide ambient temperature < +60°C
E31
Faulty EEPROM checksum,
hardware error
Service required if fault occurs repeatedly
®
Reship LMC J 0040 3 for repair
E51 Failure to set avalanche voltage
1. straylight
2. hardware error
1. Check target reflectance and ambient light
(steady light), make sure that neither target
not entry opening of LMC J 0040 3 is exposed to
light from reflecting surfaces, projectors
or
sun)
2. Service required
®
reship for repair
E52
Laser current too high / laser
defective
Reship LMC J 0050 3 for repair
Contact technical support
Przeglądanie stron 34
1 2 ... 30 31 32 33 34 35 36 37 38 39

Komentarze do niniejszej Instrukcji

Brak uwag